Transmission lines power measurements for the 110 GHz electron cyclotron heating system on DIII-D and gyrotron operational performance
Author
Cengher, M. ; Lohr, J. ; Ponce, D. ; Gorelov, Y.A. ; Moeller, C.P. ; Shapiro, M.
Author_Institution
Gen. Atomics, San Diego, CA, USA
fYear
2010
fDate
5-10 Sept. 2010
Firstpage
1
Lastpage
2
Abstract
Operational trends for the six-gyrotron electron cyclotron heating system on DIII-D are presented. Losses in the transmission lines were measured and values close to theoretical were attained for one of the lines with the existing components. Improved alignment and reduction of the number of miter bends in the lines will increase the power transmitted through the waveguide to the DIII-D tokamak.
Keywords
Tokamak devices; gyrotrons; plasma radiofrequency heating; transmission lines; DIII-D tokamak; electron cyclotron heating system; frequency 110 GHz; gyrotron operational performance; transmission lines power measurement; Gyrotrons; Loss measurement; Power measurement; Power transmission lines; Propagation losses; Temperature measurement; Transmission line measurements;