Abstract :
High-power impulse magnetron sputtering (HiPIMS) is a common way to create a high- and dense-ionized metallic vapor without the use of an alternative ionizing device, like radio frequency loops. HiPIMS has been used to perform the deposition of platinum thin films to control their morphology. This feature, known to depend on the energy of the Pt species incoming onto the substrate during the deposition, has to be carefully studied. Therefore, it is necessary to study the ions energy distribution during the sputtering pulse and to follow its evolution with the HiPIMS regime. Pictures of this evolution are presented.
Keywords :
metallic thin films; platinum; sputter deposition; Pt; alternative ionizing device; dense-ionized metallic vapor; high-ionized metallic vapor; high-power impulse magnetron sputtering voltage; morphology; platinum thin film deposition; radiofrequency loops; sputtering pulse; time-resolved platinum ions energy distributions; Distortion measurement; Energy measurement; Ions; Mass spectroscopy; Platinum; Sputtering; Voltage measurement; Energy resolution; magnetrons; plasma diagnostics; plasma materials processing; plasma measurements; plasma properties; platinum; sputtering; sputtering.;
fLanguage :
English
Journal_Title :
Plasma Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-3813
Type :
jour
DOI :
10.1109/TPS.2014.2325061
Filename :
6824808
Link To Document :
بازگشت