• DocumentCode
    2715972
  • Title

    About calibration features of microwave noise meter

  • Author

    Gusinskiy, A.V. ; Dzisiak, A.B. ; Kostrikin, A.M.

  • fYear
    2002
  • fDate
    9-13 Sept. 2002
  • Firstpage
    532
  • Lastpage
    533
  • Abstract
    Microwave noise meter measurement accuracy depends both on the measurement method and the method selected for meter calibration. For amplitude noise measurement, using the direct detection method, it is necessary to know the value of coefficient which characterizes the shape of the diode detection curve. In addition, it is necessary to know the steepness of the phase detector for phase noise calibration.
  • Keywords
    calibration; electric noise measurement; microwave detectors; microwave measurement; phase noise; diode detection curve shape coefficients; direct detection amplitude noise measurement; microwave measurement methods; microwave noise meter calibration features; microwave noise meter measurement accuracy; phase detector steepness; phase noise calibration; Calibration; Detectors; Diodes; Microwave measurements; Microwave theory and techniques; Noise measurement; Noise shaping; Phase detection; Phase noise; Shape measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave and Telecommunication Technology, 2002. CriMiCo 2002. 12th International Conference
  • Print_ISBN
    966-7968-12-X
  • Type

    conf

  • DOI
    10.1109/CRMICO.2002.1137342
  • Filename
    1137342