  • Abstract
    Heartbeats can be measured at a distance using radar to record the chest movements. The physiological motion appear as modulations in both phase and amplitude in the radar recording. In this paper, a single reflector model of the heartbeat is used to estimate the chest motion and find the movement in millimeters. Experimental results from 10-18GHz measurements are presented, and the validity of the estimation discussed.
  • Keywords
    amplitude modulation; cardiology; motion estimation; phase modulation; radar; amplitude modulation; chest movement estimation; frequency 10 GHz to 18 GHz; heartbeats; phase modulation; physiological motion; radar modulation; single reflector model; Estimation; Frequency measurement; Frequency modulation; Heart beat; Phase modulation; Radar;