• DocumentCode
    2717452
  • Title

    On-line monitoring of generators and steam turbines

  • Author

    Jenkins, M.P.

  • Author_Institution
    Condition Monitoring Sect., Parsons Power Generation Syst. Ltd., Newcastle upon Tyne, UK
  • fYear
    1995
  • fDate
    34729
  • Firstpage
    42491
  • Lastpage
    42495
  • Abstract
    This paper outlines the applications of on-line condition monitoring to steam turbine-generators and illustrate the field by describing two individual on-line monitors (thermal stress monitor and stator coolant monitor) that have been developed. Finally the fully integrated approach to condition monitoring under development is described
  • Keywords
    computerised monitoring; cooling; power engineering computing; stators; steam turbines; thermal stresses; turbogenerators; generators; on-line condition monitoring; stator coolant monitor; steam turbines; thermal stress monitor;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Condition Monitoring of Electrical Machines, IEE Colloquium on
  • Conference_Location
    London
  • Type

    conf

  • DOI
    10.1049/ic:19950100
  • Filename
    478169