• DocumentCode
    2717498
  • Title

    Adaptive Fuzzy Control Approach for Enhancement of Electron Magnetic Resonance Tomograms

  • Author

    Murugesan, R. ; Krishna, Murali C. ; Alli, P.

  • Author_Institution
    Madurai Kamaraj Univ., Madurai
  • Volume
    3
  • fYear
    2007
  • fDate
    13-15 Dec. 2007
  • Firstpage
    349
  • Lastpage
    354
  • Abstract
    Electron magnetic resonance imaging (EMRI), a technique akin to MRI, is fast emerging as a functional imaging modality. But, the poor SNR, originating from the low frequency operation of the EMRI scanner as well as the toxicity-limited dose of the exogenously administrated imaging agents, has hindered the development of EMRI to a viable biomedical technology. Hence novel image enhancement techniques are in need to enhance the potential of EMRI. In this paper, we propose one such system based on a fuzzy control filtering approach, using adaptively varying membership functions and incorporating fuzzy associative memory (FAM) with conventional multilevel median filter (MLMF). The performance of the system is tested using in vivo EMR images, acquired from a continuous wave (CW) radio frequency (RF) EMR imager and is evaluated visually as well as by computing quantitative metrics such as root mean square error (RMSE) and peak signal to noise ratio (PSNR). Visual and quantitative evaluation show fuzzy filters, especially the one with a new parabolic membership function, to outperform the conventional MLMF method.
  • Keywords
    adaptive control; biomedical MRI; fuzzy control; image enhancement; median filters; medical control systems; medical image processing; tomography; adaptive fuzzy control; adaptive varying membership functions; biomedical technology; continuous wave radio frequency electron magnetic resonance imaging; electron magnetic resonance tomogram; functional imaging modality; fuzzy associative memory; fuzzy control filtering approach; image enhancement; imaging agents; multilevel median filter; parabolic membership function; peak signal to noise ratio; root mean square error; scanner; Adaptive control; Adaptive filters; Biomedical imaging; Electrons; Fuzzy control; Magnetic resonance; Magnetic resonance imaging; PSNR; Programmable control; Radio frequency;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Conference on Computational Intelligence and Multimedia Applications, 2007. International Conference on
  • Conference_Location
    Sivakasi, Tamil Nadu
  • Print_ISBN
    0-7695-3050-8
  • Type

    conf

  • DOI
    10.1109/ICCIMA.2007.210
  • Filename
    4426393