Abstract :
In this extended abstract we discuss and propose a mechanism to estimate clock parameters between two clocks using TDC. Simultaneously, we have proposed a ground truth capture methodology for clock error measurements. In particular, we have proposed an accurate way of measuring clock phase ground truth at any instant in time using delay lines in FPGA. Accuracy of clock phase ground truth measurement can be up to 16 ps. We have estimated clock parameters from measurements and have compared it with clock ground truth obtained using suggested methods. Relative frequency errors are estimated with RMSE of 0.46 Hz and phase error is estimated with RMSE of 0.29 ns.
Keywords :
clocks; delay lines; field programmable gate arrays; least mean squares methods; measurement errors; phase estimation; synchronisation; time-digital conversion; FPGA; RMSE; TDC; clock error measurement; clock phase ground truth measurement; delay lines; frequency 0.46 Hz; ground truth capture; phase error; precise clock parameter estimation; relative frequency errors estimation; time 0.29 ns; Clocks; Delays; Field programmable gate arrays; Frequency measurement; Phase measurement; Synchronization;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Clock Synchronization for Measurement, Control, and Communication (ISPCS), 2014 IEEE International Symposium on
Conference_Location :
Austin, TX
Print_ISBN :
978-1-4799-2698-5
Type :
conf
DOI :
10.1109/ISPCS.2014.6948696
Filename :
6948696
Link To Document :
بازگشت