Title :
Bayesian fisher information criterion for sampling optimization in ASL-MRI
Author :
Sanches, João ; Sousa, Inês ; Figueiredo, Patrícia
Author_Institution :
Inst. for Syst. & Robot., Lisbon, Portugal
Abstract :
Pulsed Arterial Spin Labeling (PASL) techniques potentially allow the absolute, non-invasive quantification of brain perfusion using Magnetic Resonance Imaging (MRI). This can be achieved by fitting a kinetic model to the data acquired at a number of inversion times (TI). Some model parameters such as the arterial transit time need to be estimated together with perfusion, while others are usually assumed to be known. The accuracy of the model estimation strongly depends on the distribution of the TI sampling points. Here, we propose a Bayesian framework for PASL perfusion estimation based on the Fisher information criterion, whereby the optimal sampling points can be determined taking into account the uncertainty of the model parameters as well as the amount of noise in the data. We show that the optimal sampling strategy for PASL depends on the a priori knowledge of the model parameters and this should therefore be taken into account.
Keywords :
belief networks; biomedical MRI; blood vessels; brain models; haemorheology; maximum likelihood estimation; optimisation; ASL-MRI; Bayesian framework; Fisher information criterion; MRI; PASL; PASL perfusion estimation; TI; arterial transit time; brain perfusion; inversion time; kinetic model; magnetic resonance imaging; optimal sampling; pulsed arterial spin labeling; Bayesian methods; Blood; Kinetic theory; Labeling; Magnetic resonance imaging; Magnetization; Parameter estimation; Sampling methods; Signal to noise ratio; Uncertainty; ASL; Bayesian; Fisher; MRI; perfusion;
Conference_Titel :
Biomedical Imaging: From Nano to Macro, 2010 IEEE International Symposium on
Conference_Location :
Rotterdam
Print_ISBN :
978-1-4244-4125-9
Electronic_ISBN :
1945-7928
DOI :
10.1109/ISBI.2010.5490127