DocumentCode
2724117
Title
Simulation of the cooling circuit with an electrically operated water pump
Author
Simic, Dragan ; Kral, Christian ; Pirker, F.
fYear
2005
fDate
7-7 Sept. 2005
Abstract
In this paper a cooling circuit with an electrically operated water pump was examined and simulated. The presented simulation results were performed with Dymola. This simulation tool is based on the modelling language Modelica. The model of the water pump was realized with time domain differential equations. The parameters of the differential equations are defined by the geometrical data of the water pump. The water pump was driven by a controlled electric motor. A battery was used as power source for the electric motor. In the proposed application the thermal behaviour of all components in the cooling circuit (engine, pipes and cooler) is modelled. For the internal combustion engine and the cooler the temperature distribution is presented. The simulated and the theoretical characteristics of the water pump will be compared.
Keywords
circuit simulation; cooling; differential equations; driver circuits; pumps; time-domain analysis; Dymola; Modelica modelling language; cooling circuit simulation; electric motor control; internal combustion engine; temperature distribution; time domain differential equation; water pump; Circuit simulation; Cooling; Differential equations; Electric motors; Fluid flow; Friction; Impellers; Internal combustion engines; Pumps; Wheels;
fLanguage
English
Publisher
ieee
Conference_Titel
Vehicle Power and Propulsion, 2005 IEEE Conference
Conference_Location
Chicago, IL
Print_ISBN
0-7803-9280-9
Type
conf
DOI
10.1109/VPPC.2005.1554567
Filename
1554567
Link To Document