• DocumentCode
    2725178
  • Title

    Analysis of transfer ratio limitations in auxiliary resonant commutated pole converters

  • Author

    Teichmann, Ralph ; Gueldner, Henry

  • Author_Institution
    Dept. of Electr. Eng./Power Electron., Tech. Univ. Dresden, Germany
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    15
  • Lastpage
    20
  • Abstract
    The decline in the DC-bus utilization due to the ARCP (auxiliary resonant commutated pole) soft switching technique is analyzed for single-phase and three phase AC/AC converters. Duty cycle boundaries and deviations from the theoretically predicted transfer ratio are derived for topologically different ARCP arrangements. The impact of the proper selection of the resonant parameters on the system design is discussed
  • Keywords
    AC-AC power convertors; commutation; resonant power convertors; switching circuits; DC-bus utilization; auxiliary resonant commutated pole converters; duty cycle boundaries; resonant parameters selection; single-phase AC/AC converters; soft switching; three phase AC/AC converters; transfer ratio limitations; Matrix converters; Resonance; Resonant inverters; Switches; Switching circuits; Switching converters; Switching frequency; Voltage control; Zero current switching; Zero voltage switching;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Congress, 2000. CIEP 2000. VII IEEE International
  • Conference_Location
    Acapulco
  • Print_ISBN
    0-7803-6489-9
  • Type

    conf

  • DOI
    10.1109/CIEP.2000.891385
  • Filename
    891385