DocumentCode :
2729921
Title :
Real time high spatial-temporal resolution flow imaging with spiral MRI using auto-calibrated SENSE
Author :
Nezafat, Reza ; Kellman, Peter ; Derbyshire, John A. ; McVeigh, Elliot R.
Author_Institution :
Dept. of Biomed. Eng., Johns Hopkins Univ. Sch. of Med., Baltimore, MD, USA
Volume :
1
fYear :
2004
fDate :
1-5 Sept. 2004
Firstpage :
1914
Lastpage :
1917
Abstract :
A novel spiral phase contrast technique was developed for high temporal and spatial resolution imaging of blood flow without cardiac gating. Spiral sampling of k-space has excellent flow properties and acquisition speed. Parallel imaging using the coil sensitivity maps can be used to reduce the imaging duration at the cost of SNR. An auto-calibrated spiral sensitivity encoding method is introduced and used for reconstruction of phase contrast images. Phase estimation for a simulated phantom using data from various acceleration rates was compared to the true phase map. To study the accuracy of the flow estimate with parallel image reconstruction, a high resolution cardiac gated experiment was performed and a subset of under-sampled data were reconstructed. The real-time experiments were performed to measure blood velocity in the ascending aorta and through the aortic valve with high spatial and temporal resolution. Temporal resolution of the flow images was improved by a factor of at least three with no cardiac gating signal with preserved spatial resolution. The results demonstrate the potential of using the technique for real-time flow imaging with improved spatial and temporal resolution.
Keywords :
biomedical MRI; blood vessels; cardiovascular system; haemodynamics; image coding; image reconstruction; image resolution; medical image processing; phantoms; aorta; auto-calibrated SENSE; auto-calibrated spiral sensitivity encoding method; blood flow; coil sensitivity maps; high resolution cardiac gated experiment; k-space; parallel image reconstruction; phase contrast image reconstruction; real time high spatial-temporal resolution flow imaging; simulated phantom; spiral MRI; spiral phase contrast technique; Blood flow; Coils; High-resolution imaging; Image reconstruction; Image resolution; Image sampling; Magnetic resonance imaging; Signal resolution; Spatial resolution; Spirals; Phase Contrast; Real-Time MRI; SENSE; Spiral;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2004. IEMBS '04. 26th Annual International Conference of the IEEE
Conference_Location :
San Francisco, CA
Print_ISBN :
0-7803-8439-3
Type :
conf
DOI :
10.1109/IEMBS.2004.1403567
Filename :
1403567
Link To Document :