• DocumentCode
    2731388
  • Title

    An iterative method for designing high reliable standalone PV systems at minimum cost for Malaysia

  • Author

    Khatib, Tamer ; Mohamed, A. ; Sopian, K. ; Mahmoud, M.

  • fYear
    2011
  • fDate
    25-28 Sept. 2011
  • Firstpage
    486
  • Lastpage
    489
  • Abstract
    In this research an iterative method for determining the optimal sizing of standalone photovoltaic (PV) system in terms of optimal sizing of PV array and battery storage is proposed. A standalone PV system energy flow is first analysed using a developed model for a standalone PV system. In finding the optimal size of PV array and battery, a long term data (1975-2005) is considered for Malaysia. Based on the results of the designed example for a PV system installed in Kuala Lumpur, the proposed method gives satisfactory optimal sizing results.
  • Keywords
    battery storage plants; iterative methods; load flow; photovoltaic power systems; Kuala Lumpur; Malaysia; PV array; battery storage; energy flow; iterative method; standalone PV system; standalone photovoltaic system; Arrays; Batteries; Educational institutions; Load modeling; Optimization; Photovoltaic systems; Solar energy; Malaysia; PV system; Solar energy; optimal sizing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics and Applications (ISIEA), 2011 IEEE Symposium on
  • Conference_Location
    Langkawi
  • Print_ISBN
    978-1-4577-1418-4
  • Type

    conf

  • DOI
    10.1109/ISIEA.2011.6108759
  • Filename
    6108759