DocumentCode :
273186
Title :
Electric field measurements adjacent to small high voltage components
Author :
Simmons, M.A. ; White, N.M.
Author_Institution :
Pirelli General plc, Eastleigh, UK
fYear :
1988
fDate :
27-30 Jun 1988
Firstpage :
297
Lastpage :
300
Abstract :
Shows that the potential distribution and hence electric stress could be mapped along the surface of a cable termination using the corona discharge voltage of a needle. The cable used is a 15 kV XLPE 70 mm2 conductor cable
Keywords :
corona; electric field measurement; high-voltage engineering; cable termination; corona discharge voltage; electric field measurement; electric stress mapping; needle; needle point corona; potential distribution; small high voltage components;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Dielectric Materials, Measurements and Applications, 1988., Fifth International Conference on
Conference_Location :
Canterbury
Print_ISBN :
0-85296-359-9
Type :
conf
Filename :
9483
Link To Document :
بازگشت