DocumentCode
2732820
Title
Contribution of Impedance Imperfection of the T-type ISNs in Measurement Uncertainty of Conducted Disturbances
Author
Sroka, Jan
Author_Institution
EMC-Testcenter Zurich AG, Zurich
fYear
2009
fDate
12-16 Jan. 2009
Firstpage
61
Lastpage
64
Abstract
Method of uncertainty estimation due to impedance imperfection of the T-type impedanced stabilisation networks (ISNs) is presented. Elaboration is performed for two cases: for measured common mode impedance of the ISN and for assumption of tolerances imposed on this impedance. Estimation is illustrated with uncertainty calculation for the ISN designed for one pair of symmetrical, unshielded lines, so called T2 ISN. There is only one publication, namely [7] in which this uncertainty is mentioned. Numbers cited in this document are underestimated compared with what is presented in this paper.
Keywords
measurement uncertainty; telecommunication networks; T-type ISN; common mode impedance; conducted disturbances; impedance imperfection; impedanced stabilisation networks; measurement uncertainty; uncertainty estimation; Couplings; Electrical resistance measurement; Electromagnetic compatibility; Impedance measurement; Inductors; Loss measurement; Measurement uncertainty; Performance evaluation; RF signals; Radio frequency;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 2009 20th International Zurich Symposium on
Conference_Location
Zurich
Print_ISBN
978-3-9523286-4-4
Type
conf
DOI
10.1109/EMCZUR.2009.4783390
Filename
4783390
Link To Document