Major refurbishment of the turbine supervisory equipment (TSE) schemes have been carried out at Cockenzie and Longannet Power Stations. Measurements of dynamic parameters on the machine are carried out. These include: shaft to cylinder differential expansion, shaft eccentricity, bearing pedestal vibration, shaft speed, thrust bearing wear, pedestal displacement and valve positions