DocumentCode :
2734794
Title :
A method to compute open area test site uncertainty using ANSI C63.4 normalized site attenuation measurement data
Author :
Heise, Edward R. ; Heise, Robert E W
Author_Institution :
Commercial & Gov. Syst., Eastman Kodak Co., Rochester, NY, USA
fYear :
1996
fDate :
19-23 Aug 1996
Firstpage :
505
Lastpage :
507
Abstract :
ANSI C63.4 provides a criterion for an ideal open area test site (OATS) as normalized site attenuation (NSA) verses frequency. Using these factors, a level of uncertainty with a stated confidence level can be calculated for a given set of measurements. This level of uncertainty can be used as a measure of the quality of a test site and provides a convenient method to assess different sites
Keywords :
ANSI standards; attenuation measurement; measurement errors; measurement standards; test facilities; ANSI C63.4; confidence level; frequency; normalized site attenuation measurement data; open area test site uncertainty; test site quality; Antenna measurements; Area measurement; Attenuation measurement; Coaxial cables; Dipole antennas; Frequency; Open area test sites; Polarization; Testing; Uncertainty;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 1996. Symposium Record. IEEE 1996 International Symposium on
Conference_Location :
Santa Clara, CA
Print_ISBN :
0-7803-3207-5
Type :
conf
DOI :
10.1109/ISEMC.1996.561422
Filename :
561422