    Sample preparation and mercury determination by stripping voltammetry in environmental objects

  • Author

    Khustenko, Larissa A. ; Larina, Liudmila N. ; Nazarov, Boris F.

  • Author_Institution
    Chem. Technol. Dept., Tomsk Polytech. Inst., Russia
  • Volume
    2
  • fYear
    2004
  • fDate
    26 June-3 July 2004
  • Firstpage
    60
  • Abstract
    A rapid and sensitive technique for mercury determination by anodic stripping voltammetry is proposed. The carbon electrode modified with gold was used as an indicator electrode. The detection limit is 0.02 μg/L for a 120 s deposition time. The influence of organic matter and inorganic interferences on the anodic stripping analysis of mercury was studied. The most popular methods of sample preparation were compared. Ozonation is the method of choice for rapid sample preparation of natural waters. For sample preparation of soil extracts the wet digestion with potassium peroxysulphate was selected. The procedure is applicable to the trace analysis of mercury(II) in different waters and soils.
  • Keywords
    electrodes; specimen preparation; voltammetry (chemical analysis); anodic stripping voltammetry; carbon electrode; indicator electrode; inorganic interferences; organic matter; ozonation; rapid sample preparation; soil extracts; wet digestion; Chemical technology; Chemistry; Costs; Electrochemical processes; Electrodes; Gold; Interference; Mercury (metals); Soil; Stability;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Science and Technology, 2004. KORUS 2004. Proceedings. The 8th Russian-Korean International Symposium on
  • Print_ISBN
    0-7803-8383-4
  • Type

    conf

  • DOI
    10.1109/KORUS.2004.1555539
  • Filename
    1555539