DocumentCode :
2739381
Title :
A 10 kVA load power quality testing facility
Author :
Gosbell, V.J. ; Perera, B.S.P. ; Cooper, P. ; Jalilian, A.
Author_Institution :
Sch. of Electr. Comput. & Telecommun. Eng., Wollongong Univ., NSW, Australia
Volume :
1
fYear :
1998
fDate :
14-18 Oct 1998
Firstpage :
249
Abstract :
The paper discusses a load testing facility to test both single and three phase loads up to 10 kVA for their susceptibility to power quality disturbances. The disturbances of concern are low frequency with components up to 1 kHz and includes lower frequency harmonics and interharmonics, sags, swells, unbalance, overvoltage, undervoltage, flicker, and frequency excursions. To deal with the above, the load testing facility includes (i) a waveform generator, (ii) a double chamber calorimeter for accurate measurement of losses, and (iii) a computer based instrumentation system. Some example applications of the facility are given
Keywords :
calorimeters; computerised instrumentation; data acquisition; load (electric); loss measurement; power supply quality; test facilities; waveform generators; 10 kVA; computer based instrumentation system; double chamber calorimeter; flicker; frequency excursions; interharmonics; load power quality testing facility; losses measurement; lower frequency harmonics; overvoltage; power quality disturbances susceptibility; sags; single phase loads; swells; three phase loads; unbalance; undervoltage; waveform generator; Electric variables measurement; Frequency; Loss measurement; Power quality; Power system harmonics; Signal generators; Testing; Voltage control; Voltage fluctuations; Voltage-controlled oscillators;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Harmonics and Quality of Power Proceedings, 1998. Proceedings. 8th International Conference On
Conference_Location :
Athens
Print_ISBN :
0-7803-5105-3
Type :
conf
DOI :
10.1109/ICHQP.1998.759895
Filename :
759895
Link To Document :
بازگشت