Title :
Seismic performance test of bolted connections between precast-concrete column and H-beam
Author_Institution :
Ulsan Univ., South Korea
fDate :
26 June-3 July 2004
Abstract :
The PCS system, which consists of precast column and steel beam, has been developed and expected to achieve effectiveness in the constructability and improve the structural performance under earthquake. Low cyclic seismic test by the ACI test program are carried out in order to verify the structural performance of the system. It was found that the system possesses the higher level of structural performance regarding strength, stiffness, energy absorption and ductility than the requirements from the criteria of the ACI.
Keywords :
beams (structures); concrete; construction components; construction industry; ductility; earthquakes; fasteners; mechanical strength; mechanical testing; steel; ACI test program; H-beam; bolted connections; building construction industry; ductility; earthquake; energy absorption; low cyclic seismic test; precast-concrete column; seismic performance test; steel beam; stiffness; strength; structural performance; Concrete; Earthquakes; Fasteners; Personal communication networks; Steel; Strain measurement; Structural beams; System testing; TV; Tensile stress;
Conference_Titel :
Science and Technology, 2004. KORUS 2004. Proceedings. The 8th Russian-Korean International Symposium on
Print_ISBN :
0-7803-8383-4
DOI :
10.1109/KORUS.2004.1555640