Title :
Time efficient and robust 3-D brain image centering and realignment using hybrid genetic algorithm
Author :
Cadieux, Sebastien ; Tanizaki, Naoaki ; Okamura, Tetsuya
Author_Institution :
Res. & Dev. Center, Sumitomo Heavy Ind. Ltd., Kanagawa, Japan
Abstract :
Describes a time efficient and robust method to center and realign three dimensional brain images obtained by positron emission tomography (PET). This is primordial for most clinical applications. The method is not affected by brain image defects. This robustness is accomplished using a stochastic sign change criterion as an optimization index. This method takes also 75% less (less than 5 minutes) time than the similar method by Minoshima et al. (1992). The calculation time reduction is achieved by combination of the use of a hybrid genetic algorithm for optimization and an “addition-only” rotation transformation
Keywords :
brain; genetic algorithms; medical image processing; positron emission tomography; 3D brain images; addition-only rotation transformation; calculation time reduction; hybrid genetic algorithm; image centering; image realignment; optimization index; positron emission tomography; robustness; stochastic sign change criterion; Application software; Biomedical imaging; Brain; Genetic algorithms; Head; Image analysis; Lesions; Positron emission tomography; Robustness; Stochastic processes;
Conference_Titel :
SICE '97. Proceedings of the 36th SICE Annual Conference. International Session Papers
Conference_Location :
Tokushima
DOI :
10.1109/SICE.1997.625011