• DocumentCode
    2741535
  • Title

    Classification of Lung Sounds during Bronchial Provocation Using Waveform Fractal Dimensions

  • Author

    Gnitecki, J. ; Moussavi, Z. ; Pasterkamp, H.

  • Author_Institution
    Department of Electrical Engineering, University of Manitoba, Winnipeg, MB, CANADA; Department of Electrical Engineering, Biology of Breathing Group, Manitoba Institute of Child Health, Winnipeg, MB, CANADA
  • Volume
    2
  • fYear
    2004
  • fDate
    1-5 Sept. 2004
  • Firstpage
    3844
  • Lastpage
    3847
  • Abstract
    Lung sounds (LS) of children after bronchoconstriction should differ from baseline LS in terms of amplitude and pattern characteristics. To test these hypotheses, time-domain and fractal based analyses have been applied to LS acquired from eight children ages 9-15 y pre- and post-methacholine challenge (MCh). Change in forced expiratory volume in 1 s after MCh ranged from -4% to -37%, with change proportional to severity of bronchoconstriction. Sounds were recorded over the posterior right lower lung lobe while subjects breathed normally for 60 s with flow measurement, and during 10 s of breath hold (BH). From root-mean-square (RMS) of LS and BH signals, signal-to-noise ratio (SNR) was determined. Two fractal dimension (FD) algorithms were applied, based on signal variance and morphology. Feature vectors for 1-nearest-neighbor classification contained FD and RMS values within flow plateau ranges. Results for LS within 75-600 Hz indicate that the combination of RMS-SNR and morphology-based FD values offers better classification of bronchoconstriction with LS, relative to using RMS-SNR with variance-based FDs and RMS-SNR alone. True positive classification was 90.3%, 63.5% and 58.3% respectively, and false positive classification was 23.4%, 24.9% and 26.1% respectively. Both RMS-SNR and FD values provide useful insight into LS changes post-bronchoconstriction.
  • Keywords
    Bronchoconstriction; fractal dimension; lung sounds; nearest neighbor classification; Acoustic testing; Fluid flow measurement; Fractals; Heart; Lungs; Measurement standards; Nearest neighbor searches; Pediatrics; Plethysmography; Time domain analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2004. IEMBS '04. 26th Annual International Conference of the IEEE
  • Print_ISBN
    0-7803-8439-3
  • Type

    conf

  • DOI
    10.1109/IEMBS.2004.1404076
  • Filename
    1404076