• DocumentCode
    2743661
  • Title

    BIONic WalkAide for correcting foot drop

  • Author

    Weber, D.J. ; Stein, R.B. ; Chan, K.M. ; Loeb, G.E. ; Richmond, F.J.R. ; Rolf, R. ; James, K. ; Chong, S.L.

  • Author_Institution
    Fac. of Phys. Educ. & Recreation, Alberta Univ., Edmonton, Alta., Canada
  • Volume
    2
  • fYear
    2004
  • fDate
    1-5 Sept. 2004
  • Firstpage
    4189
  • Lastpage
    4192
  • Abstract
    The goal of this study was to test the feasibility and efficacy of using microstimulators (BIONs™) to correct foot drop, the first human application of BIONs in functional electrical stimulation (FES). A prototype BIONic foot drop stimulator was developed by modifying a WalkAide2 stimulator to control BION stimulation of the ankle dorsiflexor muscles. BION stimulation was compared with surface stimulation of the common peroneal nerve provided by a normal WalkAide2 foot drop stimulator. Compared to surface stimulation, we found that BION stimulation of the deep peroneal nerve produces a more balanced ankle flexion movement without everting the foot. A 3-D motion analysis was performed to measure the ankle and foot kinematics with and without stimulation. Without stimulation, the toe on the affected leg drags across the ground. The BIONic WalkAide elevates the foot such that the toe clears the ground by 3 cm, which is equivalent to the toe clearance in the unaffected leg. The physiological cost index (PCI) was used to measure effort during walking. The PCI is high without stimulation (2.29 ± 0.37; mean ± S.D.) and greatly reduced with surface (1.29 ± 0.10) and BION stimulation (1.46 ± 0.24). Also, walking speed is increased from 9.4 ± 0.4 m/min. without stimulation to 19.6 ± 2.0 m/min. with surface and 17.8 ± 0.7 m/min. with BION stimulation. We conclude that functional electrical stimulation with BIONs is a practical alternative to surface stimulation and provides more selective control of muscle activation.
  • Keywords
    bioelectric phenomena; gait analysis; neuromuscular stimulation; prosthetics; 3-D motion analysis; BIONic WalkAide; WalkAide2 foot drop stimulator; ankle dorsiflexor muscles; balanced ankle flexion movement; common peroneal nerve; foot drop correction; functional electrical stimulation; microstimulators; physiological cost index; surface stimulation; walking; Foot; Humans; Leg; Legged locomotion; Motion analysis; Muscles; Neuromuscular stimulation; Performance evaluation; Prototypes; Testing; BION; FES; foot drop; spinal cord injury; stroke;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2004. IEMBS '04. 26th Annual International Conference of the IEEE
  • Conference_Location
    San Francisco, CA
  • Print_ISBN
    0-7803-8439-3
  • Type

    conf

  • DOI
    10.1109/IEMBS.2004.1404169
  • Filename
    1404169