Title :
Coaxial power sensor calibration with adaptor by direct comparison transfer
Author :
Cai, Yang ; Shan, Yueyan ; Lin, Zhiping ; Neo, Hoon
Author_Institution :
Sch. of Electr. & Electron. Eng., Nanyang Technol. Univ., Singapore, Singapore
Abstract :
This paper describes the practical development of National Metrology Centre (NMC)´s microwave power sensor calibration system using the direct comparison transfer method based on previous developed coaxial broadband calibration system. We propose an analytical method to deal with the adaptor problem to treat the connector difference and power level difference of DUTs from the reference standards. The model is established by using signal flow graph together with non-touching loop rule analyses. The calibration transfer equation is derived through the transfer functions. The uncertainties are evaluated for the complex reflection coefficient inputs following the internationally recommended guidelines.
Keywords :
calibration; coaxial waveguides; electromagnetic wave reflection; measurement uncertainty; microwave measurement; power measurement; transfer functions; waveguide components; National Metrology Centre; adaptor problem; calibration transfer equation; coaxial broadband calibration system; coaxial power sensor calibration; complex reflection coefficient; direct comparison transfer method; measurement uncertainty; microwave power sensor calibration system; nontouching loop rule analysis; power level difference; reference standard; signal flow graph; transfer function; Calibration; Equations; Flow graphs; Mathematical model; Measurement uncertainty; Standards; Uncertainty; Direct comparison transfer method; measurement modeling with adaptor; measurement uncertainty; microwave power sensor calibration;
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2012 Conference on
Conference_Location :
Washington, DC
Print_ISBN :
978-1-4673-0439-9
DOI :
10.1109/CPEM.2012.6250675