• DocumentCode
    2744248
  • Title

    Scattering parameter measurement comparison between NMC and INRIM on Vector Network Analyzer using WR15 and WR10 connectors

  • Author

    Shan, Yueyan ; Oberto, Luca ; Meng, Yu Song ; Neo, H. ; Brunetti, L. ; Sellone, Marco

  • Author_Institution
    Nat. Metrol. Centre (NMC), A*STAR (Agency for Sci., Technol. & Res.), Singapore, Singapore
  • fYear
    2012
  • fDate
    1-6 July 2012
  • Firstpage
    96
  • Lastpage
    97
  • Abstract
    This paper describes a bilateral comparison between two national metrology institutes, NMC, A*STAR from Singapore and INRIM from Italy, concerning scattering parameter measurements with WR15 (50 to 75 GHz) and WR10 (75 to 110 GHz) waveguides.
  • Keywords
    S-parameters; millimetre wave measurement; network analysers; waveguide couplers; A*STAR; INRIM; NMC; National Metrology Institute; WR10 connector; WR15 connector; frequency 50 GHz to 110 GHz; scattering parameter measurement; vector network analyzer; Calibration; Frequency measurement; Millimeter wave measurements; Reflection; Scattering parameters; Temperature measurement; Uncertainty; Bilateral comparison; measurement uncertainty; scattering parameters; waveguide;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2012 Conference on
  • Conference_Location
    Washington, DC
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4673-0439-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2012.6250678
  • Filename
    6250678