DocumentCode :
2745017
Title :
Measurement of the level dependence in phase angle errors of the high current shunts
Author :
Pan, Xianlin ; Wang, Qi ; Zhang, Jiangtao ; Zeng, Shufan ; Chen, Wancai
Author_Institution :
Harbin Inst. of Technol., Harbin, China
fYear :
2012
fDate :
1-6 July 2012
Firstpage :
160
Lastpage :
161
Abstract :
This paper describes a method for the measurement of the level dependence in the phase angle errors of the high current shunts against a current-voltage converter with the lock-in amplifier. The measurement results of Fluke A40B and metal foil shunts developed by BEV Austria of 100 A at rated and half-rated current at 100 kHz are presented.
Keywords :
current transformers; instrument transformers; measurement errors; phase measurement; power measurement; transfer standards; Fluke A40B; current 100 A; current-voltage converter; frequency 100 kHz; high current shunts; level dependence; lock-in amplifier; metal foil shunts; phase angle error; Amplifiers; Current measurement; Current transformers; Measurement uncertainty; Metals; Phase measurement; Voltage measurement; Level dependence in phase angle error; current transformer; current-voltage converter; high current shunts;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2012 Conference on
Conference_Location :
Washington, DC
ISSN :
0589-1485
Print_ISBN :
978-1-4673-0439-9
Type :
conf
DOI :
10.1109/CPEM.2012.6250722
Filename :
6250722
Link To Document :
بازگشت