  • Title

    Study and development of a measurement set-up for high impulse currents

  • Author

    Istrate, D. ; Blanc, I. ; Fortune, D.

  • Author_Institution
    Lab. Nat. de Metrol. et d´´Essai (LNE, Trappes, France
  • fYear
    2012
  • fDate
    1-6 July 2012
  • Firstpage
    224
  • Lastpage
    225
  • Abstract
    The understanding of high current events such as short circuit transients and impulse currents is important for the management of power quality. The work carried out and presented in this paper is focused on the characterization of commercial current transducers for on-site grade and traceable measurements of 8/20 μs (rise/fall time) impulse currents up to 60 kA peak value with a target uncertainty of 0.1 % for the complete measurement system. The investigation method consists in using two current transducers (Pearson and Rogowski coils) that will detect simultaneously the same impulse current.
  • Keywords
    electric current measurement; power supply quality; short-circuit currents; transducers; Pearson coil; Rogowski coil; commercial current transducers; current 60 kA; current transducers; high impulse currents; impulse currents; measurement set-up; power quality management; short circuit transients; Calibration; Coils; Current measurement; Measurement uncertainty; Time measurement; Transducers; Uncertainty; Impulse current; Pearson current monitor; Rogowski coil; comparison technique; measurement dynamics;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2012 Conference on
  • Conference_Location
    Washington, DC
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4673-0439-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2012.6250883
  • Filename
    6250883