  • Abstract
    By employing standard FFT methods, the phase of a single tone of a mains energy waveform can be derived from measurements made using an Agilent 3458A. Phase errors arising from the finite sampling interval resolution can be corrected when the signal frequency is known. Knowing the form of the resulting spectral leakage errors can assist in correcting the measured phase to within 0.002°. In the SSDC mode of the 3458A, these phase errors reveal an unexpected step change in the 3458A´s effective sampling interval resolution as the sampling rate is changed.
  • Keywords
    fast Fourier transforms; frequency measurement; phase measurement; power measurement; sampling methods; Agilent 3458A; FFT methods; SSDC mode; fast Fourier transforms; finite sampling interval resolution; mains energy waveform; mains power frequencies; phase errors; phase measurement; signal frequency; spectral leakage errors; Equations; Frequency measurement; Mathematical model; Phase measurement; Power measurement; Signal resolution; Standards; Fast Fourier transforms; phase measurement; power measurement; spectral leakage; voltmeters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2012 Conference on
  • Conference_Location
    Washington, DC
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4673-0439-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2012.6250910
  • Filename
    6250910