DocumentCode
2749384
Title
A model for recovering the conducibility of a conductive material from measurement inside reverberation chamber
Author
Cerri, Graziano ; Russo, Paola ; Primiani, Valter Mariani
Author_Institution
Dipt. di Ing. Biomedica, Elettron. e Telecomun., Univ. Politec. delle Marche, Ancona, Italy
fYear
2009
fDate
11-12 June 2009
Firstpage
1
Lastpage
4
Abstract
An electromagnetic model for recovering the conducibility of a sample material is developed. The procedure is based on scalar measurements inside a reverberation chamber.
Keywords
conducting materials; dielectric measurement; reverberation chambers; conductive material; dielectric parameter measurement; electromagnetic model; measurement inside reverberation chamber; scalar measurement; Biological materials; Biomedical materials; Biomedical measurements; Conducting materials; Conductivity measurement; Dielectric materials; Dielectric measurements; Permittivity measurement; Reverberation chamber; Transmission line theory; dielectric parameter; reverberation chamber; waveguide;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility - EMC Europe, 2009 International Symposium on
Conference_Location
Athens
Print_ISBN
978-1-4244-4107-5
Electronic_ISBN
978-1-4244-4108-2
Type
conf
DOI
10.1109/EMCEUROPE.2009.5189712
Filename
5189712
Link To Document