  • Abstract
    In a cross capacitor with guard electrodes, the equivalent electrical length is sensitive to any variation in the cross section of the main electrodes unless measures are taken to compensate for this. The problem arises particularly in the case of a moveable guard electrode, which is conventionally fitted with a nosepiece of such geometry as to compensate for variations in the geometry of the main electrodes from one guard position to another. In the new NIM cross capacitor an alternative approach, in which a fraction of the measuring voltage is applied to an isolated electrode in the face of the guard electrode, has been investigated. Results indicate that this active nosepiece performs better than an equivalent geometrical compensating nosepiece.
  • Keywords
    capacitance measurement; capacitors; compensation; electrodes; geometry; voltage measurement; NIM; cross capacitor; electrical compensation method; equivalent electrical length; equivalent geometrical compensating nosepiece; model testiing; moveable guard electrode; nosepiece fitting; voltage measurement fraction; Bars; Capacitance; Capacitance measurement; Capacitors; Electrodes; Face; Voltage measurement; Close approach nonlinearity; Electrical end; End-effect error; Modified active nosepiece; Nosepiece;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2012 Conference on
  • Conference_Location
    Washington, DC
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4673-0439-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2012.6251003
  • Filename
    6251003