DocumentCode :
2750614
Title :
Long-term calibration results of 10 mH and 100 mH standard inductors using a reactance compensation method
Author :
Sakamoto, N.
Author_Institution :
Nat. Metrol. Inst. of Japan (NMIJ), Nat. Inst. of Adv. Ind. Sci. & Technol., Tsukuba, Japan
fYear :
2012
fDate :
1-6 July 2012
Firstpage :
582
Lastpage :
583
Abstract :
Standard inductors of 10 mH and 100 mH have been calibrated at 1000 Hz and 1592 Hz by a simple calibration system using a commercially available LCR meter since 2004 at NMIJ. Long-term behavior of the inductance is roughly stable within the standard uncertainties which were obtained to be around 10 ppm.
Keywords :
calibration; electric current measurement; electric resistance measurement; inductance measurement; inductors; LCR meter; NMIJ; frequency 1000 Hz; frequency 1592 Hz; inductance measurement; long-term calibration; reactance compensation method; standard inductors; Calibration; Capacitors; Inductance; Inductance measurement; Inductors; Standards; Uncertainty; Calibration; LCR meter; compensation method; impedance measurement; inductance measurement; standard capacitor; standard inductor;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2012 Conference on
Conference_Location :
Washington, DC
ISSN :
0589-1485
Print_ISBN :
978-1-4673-0439-9
Type :
conf
DOI :
10.1109/CPEM.2012.6251063
Filename :
6251063
Link To Document :
بازگشت