DocumentCode
2752121
Title
Conversion between the method of measurement of electrified railway radio disturbance in our country and the method stipulated by EN standard
Author
Zhang Chen ; Huang Jidong
Author_Institution
China Acad. of Railway Sci., China
fYear
2003
fDate
4-7 Nov. 2003
Firstpage
596
Lastpage
600
Abstract
By test and statistical analysis, this paper derives a conversion coefficient between our method of measurement of electrified railway radio disturbance (ERRD) and the method stipulated by the EN50-121 standard. Then the evaluation of the level of ERRD in the state was carried out with the limit stipulated by the EN standard. This provides the foundation for us to apply the EN standard in China in the future.
Keywords
measurement standards; radiofrequency interference; railway electrification; statistical analysis; China; EN50-121 standard; ERRD; conversion coefficient; electrified railway radio disturbance; measurement method; statistical analysis; Antenna measurements; Bellows; Frequency; Joining processes; Measurement standards; Polarization; Rail transportation; Railway electrification; Statistical analysis; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Environmental Electromagnetics, 2003. CEEM 2003. Proceedings. Asia-Pacific Conference on
Conference_Location
Hangzhou, China
Print_ISBN
7-5635-0802-3
Type
conf
DOI
10.1109/CEEM.2003.238489
Filename
1282402
Link To Document