• DocumentCode
    2752297
  • Title

    Electrical diagnostics in a HV corona streamer discharge setup: Improved current measurement through electromagnetic frequency response analysis

  • Author

    Clevis, T.T.J. ; Nijdam, S. ; van Deursen, A.P.J.

  • Author_Institution
    Dept. Appl. Phys., Eindhoven Univ. of Technol., Eindhoven, Netherlands
  • fYear
    2012
  • fDate
    17-21 Sept. 2012
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Current diagnostics of a high voltage corona discharge setup are analyzed, because the presence of high amplitude oscillations prohibited to obtain a realistic current signal. By means of an electromagnetic computation in FEKO, the observed oscillations have been identified. Current distributions indicated setup improvement by adding a 50Ω damping resistor in the circuit. A realistic current signal is now obtained.
  • Keywords
    corona; current distribution; discharges (electric); frequency response; resistors; FEKO electromagnetic computation; HV corona streamer discharge setup; current diagnostics; current distributions; current measurement; current signal; damping resistor; electrical diagnostics; electromagnetic frequency response analysis; high amplitude oscillations; high voltage corona discharge setup; resistance 50 ohm; Current measurement; Discharges (electric); Frequency measurement; Frequency response; Oscillators; Resonant frequency; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility (EMC EUROPE), 2012 International Symposium on
  • Conference_Location
    Rome
  • ISSN
    2325-0356
  • Print_ISBN
    978-1-4673-0718-5
  • Type

    conf

  • DOI
    10.1109/EMCEurope.2012.6396866
  • Filename