DocumentCode
2752297
Title
Electrical diagnostics in a HV corona streamer discharge setup: Improved current measurement through electromagnetic frequency response analysis
Author
Clevis, T.T.J. ; Nijdam, S. ; van Deursen, A.P.J.
Author_Institution
Dept. Appl. Phys., Eindhoven Univ. of Technol., Eindhoven, Netherlands
fYear
2012
fDate
17-21 Sept. 2012
Firstpage
1
Lastpage
4
Abstract
Current diagnostics of a high voltage corona discharge setup are analyzed, because the presence of high amplitude oscillations prohibited to obtain a realistic current signal. By means of an electromagnetic computation in FEKO, the observed oscillations have been identified. Current distributions indicated setup improvement by adding a 50Ω damping resistor in the circuit. A realistic current signal is now obtained.
Keywords
corona; current distribution; discharges (electric); frequency response; resistors; FEKO electromagnetic computation; HV corona streamer discharge setup; current diagnostics; current distributions; current measurement; current signal; damping resistor; electrical diagnostics; electromagnetic frequency response analysis; high amplitude oscillations; high voltage corona discharge setup; resistance 50 ohm; Current measurement; Discharges (electric); Frequency measurement; Frequency response; Oscillators; Resonant frequency; Voltage measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility (EMC EUROPE), 2012 International Symposium on
Conference_Location
Rome
ISSN
2325-0356
Print_ISBN
978-1-4673-0718-5
Type
conf
DOI
10.1109/EMCEurope.2012.6396866
Filename
6396866
Link To Document