Title
Time domain measurements of dielectric response in oil-paper insulation systems
Author
Houhanessian, Vahe Der ; Zaengl, Walter S.
Author_Institution
High Voltage Lab., Swiss Federal Inst. of Technol., Zurich, Switzerland
Volume
1
fYear
1996
fDate
16-19 Jun 1996
Firstpage
47
Abstract
The results of dielectric response measurements in the time and frequency domain on homogeneous impregnated pressboard and on series arrangements of pressboard sheets and oil ducts are presented. A simple equivalent circuit is proposed to model oil-paper insulation systems for single impregnated pressboard sheets as well as for multi-layer arrangements. This equivalent circuit which is derived from relaxation current measurements is then used to calculate recovery voltages as well as the frequency-dependent permittivity. Finally it is shown that the same procedure can be applied to quantify the dielectric response properties on high voltage power transformers
Keywords
electric breakdown; equivalent circuits; insulation testing; paper; power transformer insulation; power transformer testing; transformer oil; dielectric response properties; equivalent circuit; frequency-dependent permittivity; high voltage power transformers; homogeneous impregnated pressboard; insulation breakdown tests; multi-layer arrangements; oil ducts; oil-paper insulation systems; pressboard sheets; recovery voltages; relaxation current measurements; time domain measurements; Current measurement; Dielectric measurements; Dielectrics and electrical insulation; Ducts; Equivalent circuits; Frequency domain analysis; Frequency measurement; Oil insulation; Petroleum; Time measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation, 1996., Conference Record of the 1996 IEEE International Symposium on
Conference_Location
Montreal, Que.
ISSN
1089-084X
Print_ISBN
0-7803-3531-7
Type
conf
DOI
10.1109/ELINSL.1996.549280
Filename
549280