  • Abstract
    Estimations of connecting leader length for grounded objects of various geometries have been performed. The data of experimental studies of protection zones for large-scale lightning-rod models of different types are presented. In experiments the connecting leaders developing towards a spark discharge from a high-voltage electrode were observed. Experimental results on protection zones are compared to calculations under Russian standards of lightning protection.
  • Keywords
    earth electrodes; lightning protection; sparks; Russian lightning protection standards; connecting leader length estimation; grounded objects; high-voltage electrode; large-scale lightning-rod model protection zones; large-scale lightning-rod model testing; spark discharge; upward connecting leader; Atmospheric modeling; Joining processes; Lead; Lightning protection; Sparks; Trajectory;