• DocumentCode
    2759349
  • Title

    Qualification test results on stator bars of large hydro generators

  • Author

    Soltani, Reza ; Lafortune, Luc ; Draper, Robert ; Khosravi, Amir

  • Author_Institution
    Andritz Hydro Ltd., Peterborough, ON, Canada
  • fYear
    2012
  • fDate
    10-13 June 2012
  • Firstpage
    596
  • Lastpage
    600
  • Abstract
    Thermal cycling and voltage endurance test (VET) are the most common tests used to qualify insulation systems of bars or coils of large rotating machines. This paper reports the results of these tests on 13.8 and 16 kV hydro generator bars. Partial discharge (PD), dissipation factor (DF) and tip-up tests are used as quantitative tests to assess the changes in condition of the insulation due to accelerated thermal and electrical aging. Breakdown tests were also performed to evaluate the effect of different stages of aging on dielectric strength of the bars.
  • Keywords
    electric machines; hydroelectric generators; machine testing; partial discharges; stators; bars insulation systems; coils insulation systems; dielectric strength; dissipation factor; electrical aging; hydro generators; partial discharge; quantitative tests; rotating machines; stator bars; thermal aging; thermal cycling; tip-up tests; voltage 13.8 kV; voltage 16 kV; voltage endurance test; Aging; Bars; IEEE standards; Insulation; Partial discharges; Stress; Voltage measurement; dissipation factor; insulation system; partial discharges; thermal cycling; voltage endurance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation (ISEI), Conference Record of the 2012 IEEE International Symposium on
  • Conference_Location
    San Juan, PR
  • ISSN
    1089-084X
  • Print_ISBN
    978-1-4673-0488-7
  • Electronic_ISBN
    1089-084X
  • Type

    conf

  • DOI
    10.1109/ELINSL.2012.6251540
  • Filename
    6251540