  • Title

    Application of a new technique to HV transmission line distance relaying

  • Author

    Wang, A.D. ; Ge, Y.Z. ; Lai, L.L. ; Johns, A.T.

  • Author_Institution
    Xi´´an Jiaotong Univ., China
  • fYear
    1991
  • fDate
    5-8 Nov 1991
  • Firstpage
    449
  • Abstract
    A new principle for digital distance relays is presented by the authors. The principle of operation is based upon the superimposed theory and modal transformation. The modal voltages and currents of the fault components are used to determine fault zones. An algorithm is proposed and implemented with an IBM-PC in FORTRAN. EMTP is used to simulate fault data on a typical 500 kV transmission system in China. With the data, the performance of the relay under different types of faults, source/line impedance ratio, fault resistance and fault inception angles has been investigated
  • Keywords
    digital simulation; microcomputer applications; power system computer control; power system protection; power transmission lines; relay protection; software packages; 500 kV; China; EMTP; FORTRAN; HV; IBM-PC; algorithm; currents; digital control; digital simulation; fault components; fault zones; modal transformation; performance; power system protection; software packages; superimposed theory; transmission line distance relaying; voltages;