• DocumentCode
    2764699
  • Title

    Fault detection, isolation and control reconfiguration of three-phase PMSM drives

  • Author

    Meinguet, Fabien ; Kestelyn, Xavier ; Semail, Eric ; Gyselinck, Johan

  • Author_Institution
    BEAMS Dept., Univ. Libre de Bruxelles (ULB), Brussels, Belgium
  • fYear
    2011
  • fDate
    27-30 June 2011
  • Firstpage
    2091
  • Lastpage
    2096
  • Abstract
    This paper deals with on-line software fault detection and isolation method for a drive composed of a fourleg inverter and a three-phase permanent magnet synchronous machine. The considered faults are single-phase open-circuit and current sensor outage. The method is based on the monitoring of the abc currents with phase-locked loops and the `CUSUM´ algorithm for the decision system. The impact of the considered faults is examined: first, in case there is no modification of the control and then in case a control reconfiguration is performed taking into account the fault diagnosis. Closed-loop operation is performed before, during and after the fault. Experimental results show that the latter case allows maintaining the drive in safe operation.
  • Keywords
    control charts; fault location; invertors; permanent magnet machines; phase locked loops; power system faults; synchronous machines; CUSUM algorithm; PMSM drives; decision system; fault control reconfiguration; fault diagnosis; fault isolation; four leg inverter; online software fault detection; permanent magnet synchronous machine; phase-locked loops; Circuit faults; Fault tolerance; Fault tolerant systems; Frequency estimation; Inverters; Phase locked loops; Torque;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics (ISIE), 2011 IEEE International Symposium on
  • Conference_Location
    Gdansk
  • ISSN
    Pending
  • Print_ISBN
    978-1-4244-9310-4
  • Electronic_ISBN
    Pending
  • Type

    conf

  • DOI
    10.1109/ISIE.2011.5984483
  • Filename
    5984483