• DocumentCode
    2764799
  • Title

    Harmonic analysis of doubly fed induction generators

  • Author

    Lindholm, Morten ; Rasmussen, Tonny W.

  • Author_Institution
    NEG Micon Control Syst., Hammel, Denmark
  • Volume
    2
  • fYear
    2003
  • fDate
    17-20 Nov. 2003
  • Firstpage
    837
  • Abstract
    This paper gives an overview of the frequency spectrum of the stator and rotor currents in a doubly fed induction generator (DFIG) used in wind power applications. The paper also presents a method to eliminate higher harmonics and interharmonics in the DFIG stator current. The method is implemented on a 40 kW laboratory model connected to the utility-grid, where the DFIG is supplied by a back-to-back 3-level NPC-converter.
  • Keywords
    asynchronous generators; harmonic analysis; harmonics suppression; power conversion harmonics; wind turbines; 40 kW; back-to-back 3-level NPC-converter; doubly fed induction generators; frequency spectrum; harmonic analysis; harmonic elimination; interharmonics; rotor currents; stator current; wind power applications; wind turbines; Control systems; Frequency; Harmonic analysis; Induction generators; Mechanical variables control; Production systems; Reactive power control; Rotors; Stators; Wind turbines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Drive Systems, 2003. PEDS 2003. The Fifth International Conference on
  • Print_ISBN
    0-7803-7885-7
  • Type

    conf

  • DOI
    10.1109/PEDS.2003.1283075
  • Filename
    1283075