Abstract :
Some of the novel image processing capabilities possible with image reconstructions from a three-dimensional data set are explored, and different methods for two-dimensional presentation of three-dimensional data are compared. The authors describe how B-scans, reflection C-scans, reflex-transmission imaging (RTI) scans, and various kinds of compensated and combined images can be reconstructed from a single acquisition of volumetric data. The authors also discuss several means for presenting these three-dimensional data, including oblique-angle imaging and stereoscopic methods. Images of phantoms illustrating some of the capabilities of volumetric data acquisition are presented
Keywords :
acoustic imaging; biomedical ultrasonics; ultrasonic absorption; ultrasonic reflection; B-scans; clinical technique; combined images; compensated images; image reconstruction; oblique-angle imaging; phantoms; reflection C-scans; reflex-transmission imaging scans; stereoscopic methods; volumetric acoustic attenuation imaging; volumetric acoustic reflection imaging; Acoustic imaging; Acoustic reflection; Attenuation; Data acquisition; Image reconstruction; Pixel; Pulse generation; Pulse measurements; Ultrasonic imaging; Ultrasonic transducers;