DocumentCode :
2770809
Title :
Implementation of ultrasound speckle filters for clinical trial
Author :
Crawford, D.C. ; Bell, D.S. ; Bamber, J.C.
Author_Institution :
Inst. of Cancer Res., Sutton, UK
fYear :
1990
fDate :
4-7 Dec 1990
Firstpage :
1589
Abstract :
Two methods are described and evaluated for compensating for the signal processing characteristics of ultrasound scanners in an adaptive speckle filter. Precorrection, in which the B-scan is transformed by the inverse of the scanner transfer function, is effective if the algorithm is calculated in full floating point arithmetic (FFP), but integer implementation results in artifacts. Postcorrection, where the speckle reference is adjusted according to its observed variation with the mean amplitude, is equally effective whether implemented in FFP or 16/8-b integer arithmetic
Keywords :
acoustic imaging; biomedical ultrasonics; computerised picture processing; medical diagnostic computing; speckle; B-scan; artifacts; clinical trial; full floating point arithmetic; ultrasound scanners; ultrasound speckle filters; Adaptive filters; Clinical trials; Image processing; Imaging phantoms; Packaging; Scattering; Signal processing algorithms; Speckle; Table lookup; Ultrasonic imaging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium, 1990. Proceedings., IEEE 1990
Conference_Location :
Honolulu, HI
Type :
conf
DOI :
10.1109/ULTSYM.1990.171636