DocumentCode
2773620
Title
Partial discharge degradation and breakdown studies in polypropylene films
Author
Thomas, Benny ; Nema, R.S.
Author_Institution
Dept. of High Voltage Eng., Indian Inst. of Sci., Bangalore, India
Volume
2
fYear
1996
fDate
16-19 Jun 1996
Firstpage
521
Abstract
Internal partial discharge characteristics are investigated on impregnated polypropylene films containing artificial cavity of well-defined dimensions, immersed in oil. Electrical breakdown studies are carried out at step-wise rising stress to evaluate constants of inverse power law model. Partial discharge pulse distribution patterns are acquired using PC interfaced multichannel analyser and statistical analysis of the discharge pulse spectrum is done by using 3-parameter Weibull distribution function. The results are compared with that for unimpregnated samples in air
Keywords
Weibull distribution; composite insulating materials; computerised instrumentation; organic insulating materials; partial discharges; polymer films; pulse height analysers; statistical analysis; 3-parameter Weibull distribution function; PC interfaced multichannel analyser; artificial cavity; breakdown studies; impregnated polypropylene films; inverse power law model; partial discharge degradation; pulse distribution patterns; statistical analysis; step-wise rising stress; unimpregnated samples; Degradation; Electric breakdown; Electrodes; Partial discharge measurement; Partial discharges; Pattern analysis; Petroleum; Pulse amplifiers; Stress; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation, 1996., Conference Record of the 1996 IEEE International Symposium on
Conference_Location
Montreal, Que.
ISSN
1089-084X
Print_ISBN
0-7803-3531-7
Type
conf
DOI
10.1109/ELINSL.1996.549397
Filename
549397
Link To Document