Title :
Influence of electrode temperature on the characteristics of a non uniform field system with a barrier
Author :
Siddagangappa, M.C. ; Mandal, D.K.
Author_Institution :
Dept. of High Voltage Eng., Indian Inst. of Sci., Bangalore, India
Abstract :
Electrode temperature controlled AC corona discharge inception voltages (CIV) of a nonuniform field electrode system and the characteristics change of CIV in the presence of a barrier is investigated. Reduction in the breakdown voltages of the gap for negative standard impulse applications was observed as the point electrode temperature reached 200°C and the characteristic occurrence was repeated in the presence of a pressboard barrier
Keywords :
composite insulating materials; corona; electric breakdown; electrodes; impulse testing; insulation testing; thermal analysis; 200 C; AC corona discharge inception voltages; breakdown voltages; composite insulation tests; electrode temperature; insulation breakdown testing; negative standard impulse; nonuniform field electrode system; pressboard barrier insulation; Corona; Current measurement; Dielectrics; Electrodes; Insulation; Plasma temperature; Solids; Temperature control; Temperature dependence; Voltage control;
Conference_Titel :
Electrical Insulation, 1996., Conference Record of the 1996 IEEE International Symposium on
Conference_Location :
Montreal, Que.
Print_ISBN :
0-7803-3531-7
DOI :
10.1109/ELINSL.1996.549404