Title :
Electric penetrations at Sizewell `B´
Author_Institution :
NEI Reyrolle, Hebburn
Abstract :
The development of controlled nuclear fission as a power source for electric generating stations has evolved into a major industry and created the need for many unique pieces of equipment. Among these are containment electrical penetrations which perform the dual function of carrying electric conductors through the containment structure surrounding the reactor, while simultaneously maintaining the pressure boundary integrity of the structure. Here, the authors describe the electric penetrations at the Sizewell B nuclear power plant
Keywords :
electric conduits; fission reactor safety; nuclear power stations; power cables; radiation protection; shielding; telecommunication cables; PWR; Sizewell B; UK; containment structure; electric conductors; electric conduits; electrical penetrations; nuclear power stations; power cables; pressure boundary integrity; shielding; telecommunication cables;
Conference_Titel :
Electrical and Control Aspects of the Sizewell B PWR, 1992., International Conference on
Conference_Location :
London
Print_ISBN :
0-85296-550-8