DocumentCode
2778190
Title
A comparison of analytical and conventional techniques for thermal endurance characterization of cable insulation
Author
Motori, A. ; Montanari, G.C. ; Centurioni, L. ; Coletti, G.
Author_Institution
Bologna Univ., Italy
Volume
2
fYear
1996
fDate
16-19 Jun 1996
Firstpage
632
Abstract
The thermal endurance characterization of ethylene-propylene rubber (EPR) insulated cables for medium voltage applications is performed by both conventional long-term life tests and resorting to an analytical technique, which is based on measurements of the oxidative stability of the insulation. It is shown that the temperature index and the halving interval provided by the two methods are very close. Comparisons are finally made with the results previously obtained applying the same procedures to high voltage EPR cables
Keywords
ethylene-propylene rubber; EPR insulated cables; cable insulation; ethylene-propylene rubber; halving interval; long-term life tests; medium voltage applications; oxidative stability; temperature index; thermal endurance characterization; Cable insulation; Cables; Insulation testing; Life testing; Medium voltage; Paramagnetic resonance; Performance analysis; Performance evaluation; Rubber; Stability analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation, 1996., Conference Record of the 1996 IEEE International Symposium on
Conference_Location
Montreal, Que.
ISSN
1089-084X
Print_ISBN
0-7803-3531-7
Type
conf
DOI
10.1109/ELINSL.1996.549424
Filename
549424
Link To Document