Title :
Streamer initiation and propagation in insulating oil in weakly non-uniform fields under impulse conditions
Author :
Badent, R. ; Kist, K. ; Schwab, A.J.
Author_Institution :
Inst. of Electr. Energy Syst. & High-Voltage Technol., Karlsruhe Univ., Germany
Abstract :
This paper deals with the investigation of prebreakdown phenomena in insulating oil in weakly nonuniform fields of rodplane geometries with gaps up to 100 mm under impulse voltages of both polarities up to 700 kV. As with the point-plane configuration, the rod-plane geometry shows a decrease of the time to breakdown with increasing voltage rate-of-rise. At a specific rate, a significantly shorter breakdown time is observed both for positive and negative polarities. Beyond this discontinuity range breakdown time decreases again but with lower rates
Keywords :
discharges (electric); electric breakdown; impulse testing; insulating oils; insulation testing; impulse conditions; insulating oil; insulation breakdown tests; point-plane configuration; prebreakdown phenomena; rod-plane geometry; streamer initiation; streamer propagation; time-to-breakdown; voltage rate-of-rise; weakly nonuniform fields; Breakdown voltage; Delay effects; Dielectrics and electrical insulation; Electric breakdown; Electrodes; Geometry; Low voltage; Oil insulation; Petroleum; Propagation delay;
Conference_Titel :
Electrical Insulation, 1996., Conference Record of the 1996 IEEE International Symposium on
Conference_Location :
Montreal, Que.
Print_ISBN :
0-7803-3531-7
DOI :
10.1109/ELINSL.1996.549446