• DocumentCode
    278214
  • Title

    Testing to breakdown-what does this tell us?

  • Author

    Fothergill, J.C.

  • Author_Institution
    Dept. of Eng., Leicester Univ., UK
  • fYear
    1991
  • fDate
    33322
  • Firstpage
    42370
  • Lastpage
    42371
  • Abstract
    Tests to establish a breakdown strength generally fall into one of three categories: establishment of suitability for an application; performance and quality tests for a given design; and proof tests to verify the quality of an item before it is released to the customer. The probability of failure in constant stress tests using the Weibull distribution is also looked at
  • Keywords
    electric breakdown; electric strength; probability; testing; Weibull distribution; constant stress tests; electric breakdown strength; failure probability; performance tests; proof tests; quality tests;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Insulation Diagnostics - Methods for Determining Quality, Remnant Life and Proof Testing, IEE Colloquium on
  • Conference_Location
    London
  • Type

    conf

  • Filename
    181376