• DocumentCode
    278625
  • Title

    Fault diagnosis in safety-critical systems

  • Author

    Fast, B.

  • Author_Institution
    AEA Technol., Warrington, UK
  • fYear
    1991
  • fDate
    33529
  • Firstpage
    42583
  • Lastpage
    42586
  • Abstract
    Considers how the fault diagnosis problem is addressed in two product ranges designed by AEA Technology, one a hard-wired automatic shutdown system (PCL) and the other a computer-based protection system (ISAT). These products though primarily produced to provide high integrity systems for the nuclear industry are equally applicable to any other safety-critical process. Failsafe design together with automatic self-testing ensure that any failure in the systems results in the associated plant being taken to a preferred safe state
  • Keywords
    automatic testing; failure analysis; fault tolerant computing; nuclear engineering computing; safety systems; ISAT; PCL; automatic self-testing; computer-based protection system; failsafe design; fault diagnosis; hard-wired automatic shutdown system; high integrity systems; inherently safe automated trip; nuclear industry; preferred safe state; pulse coded logic; safety-critical systems;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Condition Monitoring for Fault Diagnosis, IEE Colloquium on
  • Conference_Location
    London
  • Type

    conf

  • Filename
    182017