• DocumentCode
    2788674
  • Title

    Co-60 total dose test of 14- and 16-bit ADCs

  • Author

    Tomasch, Georg ; Harboe-Sørensen, Reno ; Müller, Reinhard ; Tzscheetzsch, Thomas

  • Author_Institution
    Max-Planck-Inst. fur Aeronomie, Katlenburg-Lindau, Germany
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    26
  • Lastpage
    31
  • Abstract
    Results of biased and unbiased Co-60 irradiation to 50 krd (Si) of 14 bit ADCs AD9243 (Analog Devices), LTC1419 (Linear Technology) and 16-bit ADS-937 (DATEL) are presented. Supply currents, reference voltage, Signal-to-Noise-and-Distortion ratio (SINAD) and standard deviation were monitored
  • Keywords
    analogue-digital conversion; gamma-ray effects; 14 bit; 16 bit; 50 krad; ADC; Analog Devices AD9243; Co-60 irradiation; DATEL ADS-937; Linear Technology LTC1419; reference voltage; signal-to-noise-and-distortion ratio; standard deviation; supply current; total dose; CMOS technology; Current supplies; Distortion; Infrared spectra; Linearity; Logic testing; Space technology; Space vehicles; Telephony; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Radiation Effects Data Workshop, 2000
  • Conference_Location
    Reno, NV
  • Print_ISBN
    0-7803-6474-0
  • Type

    conf

  • DOI
    10.1109/REDW.2000.896265
  • Filename
    896265