The relationship between resonant control and repetitive control is investigated in this paper. Resonant control and repetitive control are compared by using them to an active power filter (APF). The stability and design of parameter with the two control methods in APF system are analyzed, and the steady-state error and transient response are also analyzed for them. The theory is verified by experiment.
Keywords :
control system synthesis; power filters; stability; transient response; APF system; active power filter; parameter design; repetitive control; resonant control; steady-state error; transient response; Active filters; Equations; Inverters; Power harmonic filters; Pulse width modulation; Resonant frequency; Steady-state; active power filter(APF); internal model; power quality; repetitive control; resonant control;