The results presented in this paper contribute to the investigations on the impact of the user´s hand on the SAR in the head. Six laboratories have assessed the peak spatial-averaged SAR at 1950 MHz for 33 commercial phones with varied form factors, either held in one of 3 different hand phantoms or without a hand. This study confirms conclusions from previously published analyses that, in some cases, the head SAR can be enhanced by the presence of the hand.
Keywords :
UHF measurement; biological effects of microwaves; mobile handsets; phantoms; frequency 1950 MHz; hand effect; hand phantoms; head SAR; measurement Interlab; mobile phones; peak spatial-averaged SAR; specific absorption rate; Antenna measurements; Antennas and propagation; Head; Laboratories; Mobile handsets; Phantoms; Specific absorption rate;